Complementary equipment

The terminal box S-G05 is easy to handle and at the same time versatile applicable accessory for micro annular gear pumps. The terminal box allows control of the pump with a potentiometer. As an alternative the pump can be remotely controlled with an external analog voltage signal 0–10 V, an external current signal (0–20 mA or 4–20 mA) or with a RS-232 interface. To set all operating parameters including calibration, ramp, step, speed, dispense/pause times and flow direction an adapted software with a serial interface RS-232 is delivered. The CE-conform installation includes an EMC module. The terminal box and micro annular gear pump can be provided optionally with an external 24 V DC power supply.

Advantages

  • For connection of micro annular gear pumps
    mzr-2505/2905/4605/7205, mzr-7245, mzr-6355/7255, mzr-2965/4665/7265
  • Compact plastic case
  • Easy handling
    potentiometer, standard connectors
  • Standard interface
    0-10 V, 0(4)-20 mA
  • Serial interface RS-232
  • Two-colored LED status indicator
  • 24 V power supply over screw terminal or DIN socket
  • Integrated EMC module

Technical data

  • Supply voltage
    24 V DC (12 – 28 V)
  • Voltage
    plug terminal, 8-pole and DIN 45323 socket
  • Pump connector
    plug connector, 8-pole
  • Serial interface
    RS-232, SUB-D plug, 9-pole
  • Speed value-input »Analog Extern«
    internal potentiometer 10 kΩ; voltage signal 0 – 10 V; current signal 0 – 20 mA or 4 – 20 mA
  • Status LED
    Ready: green; fault: red
  • Output »Fault Out«
    Open collector max. UB / 30 mA; no error: connected to GND; as input: low 0...0.5 V / high 4 V...UB
  • Protection class
    IP 20
  • Operating temperature range
    0 … +50 °C (+32 … +122 °F)
  • Dimensions (L x W x H)
    approx. 100 x 92 x 35 mm
  • Weight
    approx. 125 g
  • Remarks
    Subject to technical changes.
  • Notice
    Even if single parameters are within the indicated performance range of technical data, certain parameter combinations may not be achievable. Single parameters may exceed their indicated performance range under adequate circumstances. For detailed evaluation please contact HNP Mikrosysteme. Actual performance may vary. Specifications are subject to change without notice. 
    This document is subject to change without notice.

Show more